Minimum Capabilities (Component) Minimum Capabilities
(Metric)
Type I Type II Type III Type IV Other
Equipment Ton

500/450 Ton Chiller
Caterpillar/York 450/500 Ton Air Cooled Chiller; Built-in pump delivering 330-1600 gpm (gallons per minute); Will operate in series or parallel operation w/multiple units; 8” flanged water fittings on exterior; Weight: 50,000 lbs; Trailer mounted (semitractor) dimensions: 40’ Long x 8’.5” Wide x 13’.5” Tall; Power requirements: 800-980 Amps at 460 volts, 3 phase, 60 hz; Temporary quick connect chilled water hose available with unit for tie in to chilled water system; Potential application examples: Single or multiple units for Computer centers, High-rise buildings, Heavy manufacturing, Airports, Universities. Setup time varies depending on hose installation, water filling, fabricating, etc...4+ hours; 4/0 Cam-Lock type quick connect cable used for power termination to source avidpromedical.com

300 Ton Chiller
Caterpillar/York 300 Ton Air Cooled Chiller; Built-in pump(s) delivering 250-800 gpm; 6” flanged water fittings on exterior; Weight: 33,000 lbs; Trailer mounted (semitractor) dimensions: 30’ Long x 8’ Wide x 13’.5” Tall; Power requirements: 600-700 Amps at 460 volts, 3 phase, 60 hz; Temporary quick connect chilled water hose available with unit for tie in to chilled water system; Potential application examples: Single or multiple units for Office buildings, Multi-story buildings, Schools, Temporary structures, Retail stores. Setup time varies depending on hose installation, water filling, fabricating, etc...3+ hours; 4/0 Cam-Lock type quick connect cable used for power termination to source

150 Ton Chiller
Caterpillar/York 150 Ton Air Cooled Chiller; Built-in pumps delivering 250-700 gpm; 6” flanged water fittings on exterior; Weight: 31,000 lbs; Trailer mounted (semitractor) dimensions: 20/30’ Long x 8’ Wide x 12’.5” Tall; Power requirements: 329-400 Amps at 460 volts, 3 phase, 60 hz; Temporary quick connect chilled water hose available with unit for tie in to chilled water system; Potential application examples: Single or multiple units for Medium office buildings, Libraries, Hotels/motels, Condominiums, Retail stores. Setup time varies depending on hose installation, water filling, fabricating, etc...2+ hours; 4/0 Cam-Lock type quick connect cable used for power termination to source

50 Ton Chiller
Caterpillar/York 50 Ton Air Cooled Chiller; Built-in pump delivering 75-200 gpm; 4” quick connect water fittings on exterior; Weight: 5,500 lbs.; Skid mounted w/ forklift pockets (8,000 lb. lift recommended) dimensions: 12’ Long x 7’.5” Wide x 8’.5” Tall; Power requirements: 125 Amps at 460 volts, 3 phase, 60 hz; Temporary quick connect chilled water hose available with unit for tie in to chilled water system. Potential application examples: Single or multiple units for Small office buildings, Tent/shelter cooling, Small-medium retail stores. Setup time varies depending on hose installation, water filling, fabricating, etc...2+ hours; 4/0 Cam-Lock type quick connect cable used for power termination to source

Custom Rental Air Handling Units: 50, 75, & 100 Tons
For delivering cold air with use of any chiller, 5,000-30,000 cfm depending on unit; 20” diameter flex duct inlets/outlets for air distribution supply/return; 4/0 Cam-Lock type quick connect cable used for power termination to source; Call for power requirements and sizing; Potential application examples: Single or multiple units for buildings w/out HVAC systems, Tent/shelter cooling, etc. Setup time varies on application 1-2 hours each

Comments:

Caterpillar equipment used for typing. Equipment not available at all locations, but CAT dealer network can acquire equipment from one another and ship. Need fresh water source for filling chilled water system. Temporary chilled water hose & 4/0 power cable available for chillers. Set up & monitoring available. Low Temp Chillers and Cooling Towers available. Air handlers require use of chillers or chilled water supply to operate.

500/450 Ton

300 Ton

150 Ton

50 Ton

Custom Rental Air Handling Unit


National Mutual Aid & Resource Management Initiative